Automatic creation of global hot spares in R28

One of the nice things I’ve seen lately on the CX4 (running FLARE R28) is the automatic creation of Hot spares. Let me explain a little what I mean. In the olden days, to assign a global hot spare on a CLARiiON, you needed to create a RAID Group with one disk in it (usually with a high number like 1024 or 2048), then bind a LUN on the RG as type Hot Spare, and then it would be assigned as a Global Hot Spare for the array. Nowadays, there’s one less click required. As soon as I create a RAID Group of typ “Hot Spare”, the array grabs and tells me that LUN XXX has been assigned as a hot spare. Okay, so it might save me two minutes a year, but I still thought it was nice that someone’s been working away feverishly on the code to make this work.

To wit, I read the following in the latest Release Notes for FLARE Release 28:
“Code has been added so that when a RAID group of type hot spare is created, it will then try to create a hot spare LUN on that RAID group (assuming the creation was successful). If the creation of the RAID group fails, then the dialog will not continue with binding the LUN. If binding the LUN fails, but the RAID group creation is successful, then you will be presented with a message stating that the RAID group has been created but the attempt to create a hot spare LUN has failed. You are instructed to try and use the Create LUN dialog to manually create it. The hot spare name format will be the following: “Hot Spare LUN XXXX” XXXX will be the last (highest) available LUN ID from the pool of available LUN IDs.

Fixed in version: 6.28.10.3.19