Boot from Dell PowerVault MD3000

I had the good (!) fortune of deploying a Dell MD3000 SAS DAS the other day attached to two Dell PowerEdge 2950 hosts running Windows 2003 x64 Standard Edition. The Dell MD3000 is a DAS storage device with SAN pretensions, offering on-board controllers, cache, and a little bit of out-of-band management. The specs are here. It’s a nice little unit as far as cheap arrays go, but it can be limited in what you can do with it. You can add a couple of MD1000 expansion modules for good measure if you feel that 15 300GB SAS drives won’t get the job done. You can directly-attach 2 nodes in a “highly-available” configuration, or 4 nodes in a non-HA configuration via 3Gbps SAS controllers. For more information, check out the English version of the manual here.

Once you’ve read the manual, you’ll realise that this sort of tray could be sold as a cheap cluster device for a typical active-passive MSCS-type deployment. Which is what I thought I’d be doing. What I didn’t read in the manual, however, was how to install Windows to the array itself, rather than using local (captive) SAS storage on the 2950 to boot from. The thinking was that, in a hardware failure scenario, the second node could be plugged into the array and used to boot from the array, with no loss of data. It’s _kind_ of a nice approach, especially given the relatively high price of clustering your average Oracle DBMS. If I had my way I’d ask just what value is being placed on the data being protected, because if you’re cutting corners on the solution, you’re looking at possible problems down the track. But I digress.

In any case the customer already had this working with 2 HP Proliant nodes and a MSA500 shelf with no local storage to be seen. So, as I said before, there’s not a lot in the manual that explains how to achieve this configuration. Here’s how to do it in 26 easy steps:

1. Install Windows on the first node’s local storage.
2. Install the Modular Disk Storage Manager application (this will include multipathing software).
3. Use the first node to initialise the array and configure required storage.
4. Register the first node as a host on the array and present storage to the host group.
5. Disable the BIOS on the PERC 5/e and install Windows on the first node again, this time you’ll see the array LUNs you configured in a previous step. It helps if you disconnect one of the HBAs first, to prevent the Windows installation routine picking up more than one path to the LUN, although during the 3 or 4 installations I did this wasn’t an issue until the host was built and it came time to initialize the LUNs with Windows.
6. Do the steps 1, 2, and 4 for the second node.

There are a few things to watch out for though. When I re-enabled the BIOS on the onboard SAS controller, Windows picked up the captive storage as Physical Disk 0, and started booting off that, even though I specified the add-in HBAs as the primary boot controllers in the system BIOS. We ended up ripping out the captive storage altogether to ensure that this wasn’t going to be an issue. Because I didn’t use the local storage for the swapfile, installing the multipathing support on the nodes would cause a blue-screen and bad things to happen, as it unloads the LUNs before inserting the drivers. I didn’t have time to call Gold Queue to work through that one. I suspect moving the pagefile to local storage would help, but I didn’t have time to test that either.

So, it’s possible, but the MD3000 isn’t necessarily the most suitable tray to throw at this type of configuration. If you’re thinking about the poor man’s cluster, you’d be better off looking at these.

*Update* I had the opportunity to go back and try disabling the BIOS on the PERC 5/i and using the captive storage for the swapfile but Windows was still seeing the disks as disk 0. So we ripped out the internal storage altogether. I also had an opportunity to test the “failover” process  by powering off the first node and firing up the second one. It ran a checkdisk and then came up okay. So it works. Technically. The engineering team in the States is apparently working on a patch for the MPIO installation routine to avoid the, er, bluescreen. So we might be able to introduce a little more resiliancy to the solution if that works.