{"id":5183,"date":"2017-05-09T03:52:31","date_gmt":"2017-05-08T17:52:31","guid":{"rendered":"https:\/\/www.penguinpunk.net\/blog\/?p=5183"},"modified":"2017-05-11T16:46:47","modified_gmt":"2017-05-11T06:46:47","slug":"dell-emc-announces-vmax-enhancements","status":"publish","type":"post","link":"https:\/\/www.penguinpunk.net\/blog\/dell-emc-announces-vmax-enhancements\/","title":{"rendered":"Dell EMC Announces VMAX Enhancements"},"content":{"rendered":"<p><strong>Disclaimer: I recently attended\u00a0<\/strong><a href=\"http:\/\/www.dellemcworld.com\/index.htm\"><strong>Dell EMC World 2017<\/strong><\/a><strong>.\u00a0 My flights, accommodation and conference pass were paid for by Dell EMC via the Dell EMC Elect program. There is no requirement for me to blog about any of the content presented and I am not compensated in any way for my time at the event.\u00a0 Some materials presented were discussed under NDA and don\u2019t form part of my blog posts, but could influence future discussions.<\/strong><\/p>\n<p><a href=\"https:\/\/www.penguinpunk.net\/blog\/wp-content\/uploads\/2017\/03\/DellEMCWorld2017.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-5079\" src=\"https:\/\/www.penguinpunk.net\/blog\/wp-content\/uploads\/2017\/03\/DellEMCWorld2017.jpg\" alt=\"\" width=\"800\" height=\"188\" srcset=\"https:\/\/www.penguinpunk.net\/blog\/wp-content\/uploads\/2017\/03\/DellEMCWorld2017.jpg 1000w, https:\/\/www.penguinpunk.net\/blog\/wp-content\/uploads\/2017\/03\/DellEMCWorld2017-300x71.jpg 300w, https:\/\/www.penguinpunk.net\/blog\/wp-content\/uploads\/2017\/03\/DellEMCWorld2017-768x180.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/a><\/p>\n<p>Dell EMC today announced some enhancmenets to its VMAX platform, along with a new all-flash model. I thought I&#8217;d run through the highlights.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>VMAX 950F<\/strong><\/p>\n<p><a href=\"https:\/\/www.penguinpunk.net\/blog\/wp-content\/uploads\/2017\/05\/VMAX_950F.png\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-5135 size-full alignright\" src=\"https:\/\/www.penguinpunk.net\/blog\/wp-content\/uploads\/2017\/05\/VMAX_950F.png\" alt=\"\" width=\"204\" height=\"493\" srcset=\"https:\/\/www.penguinpunk.net\/blog\/wp-content\/uploads\/2017\/05\/VMAX_950F.png 204w, https:\/\/www.penguinpunk.net\/blog\/wp-content\/uploads\/2017\/05\/VMAX_950F-124x300.png 124w\" sizes=\"auto, (max-width: 204px) 100vw, 204px\" \/><\/a><\/p>\n<p>Dell EMC are saying that the 950F offers a &#8220;68% increase over the VMAX 850F&#8221;.\u00a0 They&#8217;re also saying that they&#8217;re seeing\u00a0&#8220;sustained low latency across most workloads&#8221;.<\/p>\n<p>&nbsp;<\/p>\n<p><em>CPUs<\/em><\/p>\n<p>The primary reason behind this improvement is the V-Brick engines being refreshed with\u00a0the latest Intel Broadwell 18-core CPUs.\u00a0 Each V-Brick has 4-18 core CPUs, bringing the total scale of a 950F up to 576 CPU cores. This\u00a0is a whole lot of cores to work with and provides some tangible benefits, including reduced response time (compared to\u00a0the VMAX 850F). A side benefit of this is that you can\u00a0now get the same performance and capacity as the 850F in a 25% smaller footprint.<\/p>\n<p>&nbsp;<\/p>\n<p><em>Scale<\/em><\/p>\n<p>The cache on the 950F is based on newer high-speed DDR4 memory, the same as the 250F.\u00a0 As with the 250F, different V-bricks can have difference cache sizes (1TB or 2TB).\u00a0You can also jam up\u00a0to 4PB of effective capacity in these things by leveraging the latest high-capacity 15.36TB\u00a0 SSDs.\u00a0 The 950F uses 16 links of 6Gb SAS for connectivity to the drives which provides the same bandwidth per engine as all other VMAX All Flash systems.<\/p>\n<p>V-Brick scaling for open systems is consistent with the 450F and 950F with V-Bricks starting with 53TB of flash capacity and scaling out storage via 13TB Flash Capacity packs.\u00a0 Host connectivity ports on a fully loaded system is 192 for open and 256 for FICON if running all mainframe.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>VMAX HYPERMAX OS Q2 release<\/strong><\/p>\n<p><em>D@RE External Key Manager<\/em><\/p>\n<p>If you&#8217;re into <a href=\"https:\/\/www.emc.com\/collateral\/white-papers\/h13936-emc-vmax3-data-rest-encryption-wp.pdf\">D@RE<\/a>, you might just be excited to hear this news.<\/p>\n<ul>\n<li>Allows customers to use a standardized key management infrastructure for D@RE across their entire environment.<\/li>\n<li>Support for external key managers using <a href=\"https:\/\/en.wikipedia.org\/wiki\/Key_Management_Interoperability_Protocol\">KMIP<\/a> (Key Management Interoperability Protocol).\u00a0 KMIP defines message formats for the manipulation of cryptographic keys on a key management server.<\/li>\n<li>Allows\u00a0customers to integrate VMAX with existing key management infrastructure.<\/li>\n<li>Leverage external key manager platforms such as Gemalto (SafeNet) KeySecure, IBM Secure Key Lifecycle Manager and other KMIP compatible servers (in the future).\u00a0\u00a0 The client runs securely on the VMAX Management Module Control Station (MMCS) inside the VMAX engine.<\/li>\n<\/ul>\n<p>This simplifies key management (i.e. key generation, escrow, recovery) for VMAX and other KMIP compatible encryption solution like Unity. It also:<\/p>\n<ul>\n<li>Simplifies security compliance across the DC;<\/li>\n<li>Provides a centralised audit log and FIPS 140-2 Level 3 compliance with Hardware Security Module (HSM) integration; and<\/li>\n<li>Allows multiple key server appliances to be clustered (even in geographically dispersed DCs) providing even higher levels of availability.<\/li>\n<\/ul>\n<p>This gives the security keys to the array back to the teams who need them.<\/p>\n<p>Customers who\u2019ve been using the embedded key manager on VMAX 3 or VMAX All Flash can non-disruptively migrate those keys to the external key manager. Dell EMC tell me this is both &#8220;painless and secure&#8221;.<\/p>\n<p>&nbsp;<\/p>\n<p><em>Secure Snaps with TimeFinder SnapVX<\/em><\/p>\n<p>Secure Snaps are a cool feature that provide a\u00a0secure option to protect against accidental deletion\u00a0or malicious attacks on\u00a0data.<\/p>\n<p>&nbsp;<\/p>\n<p><em>ProtectPoint for VMAX<\/em><\/p>\n<p><a href=\"https:\/\/www.emc.com\/collateral\/data-sheet\/h13167-protectpoint-ds.pdf\">ProtectPoint<\/a> support now extends to Microsoft SQL Server and Microsoft Exchange. You can now backup Microsoft SQL and Exchange directly to Data Domain.<\/p>\n<p>Also new\u00a0is the Instant Recovery feature for File Systems. Once a file system restore is initiated the data is immediately accessible to the host. Any application recovery workflow that uses file systems can benefit from this.<\/p>\n<p>&nbsp;<\/p>\n<p><em>RecoverPoint<\/em><\/p>\n<p>In what I think is great news, RecoverPoint is now available for VMAX3 and VMAX AF platforms. With this you get:<\/p>\n<ul>\n<li>Heterogeneous replication, with support for\u00a0XtremIO, UNITY, VNX, VMAX, VMAX2, and\u00a0third-party arrays via VPLEX;<\/li>\n<li>Granular recovery\u00a0from particular points in time (meaning RPOs as low as a minute).<\/li>\n<\/ul>\n<p>RecoverPoint uses VMAX TimeFinder SnapVX local snapshot technology. The SnapVX-based replication relies on the delta between consecutive snapshots. Note that\u00a0the data differential is further compressed and deduped to minimize the WAN bandwidth consumption.<\/p>\n<p>RecoverPoint:<\/p>\n<ul>\n<li>Is supported on both VMAX3 (100K\/200K\/400K) and VMAX All Flash platforms: VMAX 250F, 450F, 850F and 950F;<\/li>\n<li>Supports flexible fan-in and fan-out configurations; and<\/li>\n<li>Requires Gen 5 or Gen 6 hardware and RecoverPoint 5.1.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><strong>Conclusion<\/strong><\/p>\n<p>VMAX isn&#8217;t the sexiest array on the block any more. There&#8217;s nothing wrong with that though. It does what it does really well. And the people buying these arrays are interested in performance and reliability. So why would you buy VMAX now when there&#8217;s a slew of alternative solutions available? Some of it is sweat equity. Shops running VMAX invariably have a big investment in processes and tools to support the VMAX environment. They work in places that don&#8217;t necessarily move at a rapid pace, or they do things that require a reliable, repeatable result. That doesn&#8217;t mean they don&#8217;t need useful things like external key management systems though. Financial services places are rife with security folk ready to put the boot into hapless storage operators in the name of compliance. But I digress.<\/p>\n<p>There aren&#8217;t a million new features in this release, but it&#8217;s nice to see some of the features finally make it to VMAX. I&#8217;m hopeful that Dell EMC continue to invest in the platform, and continue to integrate useful protection tools such as ProtectPoint and Secure Snaps across the portfolio. The\u00a0VMAX 950F is orderable this month and will be generally available in June. You can read more about it in a blog post from Dell EMC <a href=\"https:\/\/blog.dellemc.com\/en-us\/dell-emc-vmax-950f-raises-bar-for-high-end-all-flash-storage\/ \u200e\">here<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Disclaimer: I recently attended\u00a0Dell EMC World 2017.\u00a0 My flights, accommodation and conference pass were paid for by Dell EMC via the Dell EMC Elect program. There is no requirement for me to blog about any of the content presented and I am not compensated in any way for my time at the event.\u00a0 Some materials [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[14,939,60,624],"tags":[520,790,940,942,992,21,489,814,1007,629],"class_list":["post-5183","post","type-post","status-publish","format-standard","hentry","category-dell","category-dell-emc-world","category-emc-storage","category-vmax","tag-announcement","tag-dell","tag-dell-emc","tag-dell-emc-world","tag-dellemcelect","tag-emc","tag-emcelect","tag-vmax","tag-vmax-af","tag-vmax3"],"_links":{"self":[{"href":"https:\/\/www.penguinpunk.net\/blog\/wp-json\/wp\/v2\/posts\/5183","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.penguinpunk.net\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.penguinpunk.net\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.penguinpunk.net\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.penguinpunk.net\/blog\/wp-json\/wp\/v2\/comments?post=5183"}],"version-history":[{"count":3,"href":"https:\/\/www.penguinpunk.net\/blog\/wp-json\/wp\/v2\/posts\/5183\/revisions"}],"predecessor-version":[{"id":5222,"href":"https:\/\/www.penguinpunk.net\/blog\/wp-json\/wp\/v2\/posts\/5183\/revisions\/5222"}],"wp:attachment":[{"href":"https:\/\/www.penguinpunk.net\/blog\/wp-json\/wp\/v2\/media?parent=5183"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.penguinpunk.net\/blog\/wp-json\/wp\/v2\/categories?post=5183"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.penguinpunk.net\/blog\/wp-json\/wp\/v2\/tags?post=5183"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}