{"id":2757,"date":"2015-05-01T08:00:11","date_gmt":"2015-04-30T22:00:11","guid":{"rendered":"https:\/\/www.penguinpunk.net\/blog\/?p=2757"},"modified":"2015-04-30T11:40:15","modified_gmt":"2015-04-30T01:40:15","slug":"emc-basics-accessing-remotelyanywhere-on-vnx-with-mcx","status":"publish","type":"post","link":"https:\/\/www.penguinpunk.net\/blog\/emc-basics-accessing-remotelyanywhere-on-vnx-with-mcx\/","title":{"rendered":"EMC &#8211; Basics &#8211; Accessing RemotelyAnywhere on VNX with MCx"},"content":{"rendered":"<p>Many moons ago I wrote a <a title=\"New Article \u2013 Accessing RemotelyAnywhere on CLARiiON\" href=\"https:\/\/www.penguinpunk.net\/blog\/new-article-accessing-remotelyanywhere-on-clariion\/\" target=\"_blank\">brief article about accessing RemotelyAnywhere on the CX4<\/a>. This was prompted by changes in Release 29 of FLARE that changed the access mechanism for remote console access on the SPs. I&#8217;ve been working on some VNX2s recently (or VNX with MCx &#8211; as EMC really would like them to be known), and I was curious as to whether the process was the same.<\/p>\n<p>Pretty much, yep.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Overview<\/strong><\/p>\n<p>Nowadays there are a few ways to access RemotelyAnywhere on the VNX SP. There are a few different ports on the array that can be used, depending on your circumstances. In some environments, where you&#8217;re not allowed to touch the customer&#8217;s network with your own gear, the service port may be more appropriate. Here&#8217;s an image of the ports from EMC. The model of VNX you&#8217;re using will dictate the layout of the ports.<\/p>\n<p><a href=\"https:\/\/www.penguinpunk.net\/blog\/wp-content\/uploads\/2015\/04\/SP_mgmt_ports.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2758\" src=\"https:\/\/www.penguinpunk.net\/blog\/wp-content\/uploads\/2015\/04\/SP_mgmt_ports.png\" alt=\"SP_mgmt_ports\" width=\"500\" height=\"348\" srcset=\"https:\/\/www.penguinpunk.net\/blog\/wp-content\/uploads\/2015\/04\/SP_mgmt_ports.png 620w, https:\/\/www.penguinpunk.net\/blog\/wp-content\/uploads\/2015\/04\/SP_mgmt_ports-300x209.png 300w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/a><\/p>\n<p>You can go via:<\/p>\n<ul>\n<li>the SP&#8217;s management port: <strong>http:\/\/&lt;SP IP address&gt;:9519<\/strong>;<\/li>\n<li>the SP&#8217;s service port: <strong>https:\/\/128.221.1.250:9519<\/strong> (SP A) or <strong>https:\/\/128.221.1.251:9519<\/strong> (SP B); and<\/li>\n<li>the SP&#8217;s serial port: <strong>https:\/\/192.168.1.1:9519<\/strong> (this assumes you&#8217;re connected via serial already &#8211; more on that below).<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><strong>Management Port<\/strong><\/p>\n<p>This is fairly straightforward, and you&#8217;ll need to be on a network that has access to the management ports.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Service Port<\/strong><\/p>\n<p>So, you&#8217;re probably already aware that the best way to connect to the service port is to set your laptop TCP\/IP settings as follows:<\/p>\n<ul>\n<li>IP Address \u2013 128.221.1.249 or 128.221.1.254<\/li>\n<li>Subnet Mask \u2013 255.255.255.248<\/li>\n<li>Default Gateway \u2013 leave blank<\/li>\n<li>DNS server entries \u2013 leave blank<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><strong>Serial Cable<\/strong><\/p>\n<p>If you want to connect via the serial cable, you&#8217;ll need to setup a PPP connection on your laptop. The following steps assume that you&#8217;ve got a USB to serial adapter and you&#8217;re using a Windows 7 machine.<\/p>\n<p><em>Device Manager<\/em><\/p>\n<ul>\n<li>Right Click on your Computer icon and Select Manage<\/li>\n<li>Click on Device Manager<\/li>\n<li>Expand Ports (COM &amp; LPT)<\/li>\n<li>Look for the USB-to-Serial Comm Port (COM##)<\/li>\n<li>The COMM number will be the one you will select during the configuration of your PPP connection.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><em>Create the COM Port<\/em><\/p>\n<ul>\n<li>Click Start -&gt; Control Panel -&gt; Phone and Modem.<\/li>\n<li>Click the &#8220;modem tab&#8221; and click Add.<\/li>\n<li>On the Install new Modem Pane, select the Don\u2019t detect my modem box, then click Next.<\/li>\n<li>Select Communications cable between two computers, then click Next.<\/li>\n<li>Select\u00a0the COM port from the previous step, then click Next.<\/li>\n<li>Click Finish.<\/li>\n<li>Highlight\u00a0the new modem and click Properties.<\/li>\n<li>Select the \u201cmodem tab\u201d\u00a0 and adjust the max speed to 115200 then click OK.<\/li>\n<li>Click OK again to exit the Phone and Modem screen.<\/li>\n<li>In the Computer Management window, disable and then re-enable the USB\u00a0Serial connection in Device Manager. Do this by right-clicking on it.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><em>Setting Up the PPP Connection<\/em><\/p>\n<ul>\n<li>Click Start -&gt; Control Panel -&gt; Network and Sharing Center, click Set up a new connection or network (at the bottom).<\/li>\n<li>Click Next, select Set up a dial-up connection and click Next.<\/li>\n<li>This screen should list modems and select the Communications cable between two computers\u00a0created above.<\/li>\n<li>On the next screen put in a random phone number.\u00a0 This is required in order to complete this step.\u00a0You need\u00a0at least one digit, but you&#8217;ll remove it later.\u00a0 Next put in the username and password and give it a name. Then click on Connect. This connection will fail displaying: Connection Failed with error 777. Click on Set up the connection anyway.<\/li>\n<li>You will get: \u201cThe connection to the Internet is ready to use\u201d. Select Close.<\/li>\n<li>The above connection should now appear in Network Connections. Open Control Panel and select Change Adapter Settings.<\/li>\n<li>Right-click on your new Modem connection and select Cancel as Default Connection.<\/li>\n<li>Right Click on your new Modem connection again and select Properties.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><em>Modify the Settings<\/em><\/p>\n<ul>\n<li>In the General tab, remove the phone number entry and leave it blank.<\/li>\n<li>In the General tab, click configure and set Max speed to 115200 and select enable hardware flow control.<\/li>\n<li>In the Options tab, click PPP settings and check that the top two boxes are selected (LCP extensions and SW compression).<\/li>\n<li>In the Security tab, check Data Encryption is Optional Encryption (connect even if no encryption) is set.<br \/>\nIn the Networking tab, check Internet Protocol Version 4 is selected and click on Properties.<\/li>\n<li>In the Networking tab, choose Internet Protocol Properties, then the Advanced button. Uncheck Use default gateway on remote network.<\/li>\n<li>Click OK.<\/li>\n<li>Click OK.<\/li>\n<li>Click OK.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><strong>Conclusion<\/strong><\/p>\n<p>Here&#8217;s what it looks like when you log in &#8211; enjoy.<\/p>\n<p><a href=\"https:\/\/www.penguinpunk.net\/blog\/wp-content\/uploads\/2015\/04\/screenshot2.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2823\" src=\"https:\/\/www.penguinpunk.net\/blog\/wp-content\/uploads\/2015\/04\/screenshot2.png\" alt=\"screenshot2\" width=\"800\" height=\"352\" srcset=\"https:\/\/www.penguinpunk.net\/blog\/wp-content\/uploads\/2015\/04\/screenshot2.png 2777w, https:\/\/www.penguinpunk.net\/blog\/wp-content\/uploads\/2015\/04\/screenshot2-300x132.png 300w, https:\/\/www.penguinpunk.net\/blog\/wp-content\/uploads\/2015\/04\/screenshot2-1024x450.png 1024w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Many moons ago I wrote a brief article about accessing RemotelyAnywhere on the CX4. This was prompted by changes in Release 29 of FLARE that changed the access mechanism for remote console access on the SPs. I&#8217;ve been working on some VNX2s recently (or VNX with MCx &#8211; as EMC really would like them to [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[125,60,5,408],"tags":[24,170,21,110,748,807,747,563],"class_list":["post-2757","post","type-post","status-publish","format-standard","hentry","category-clariion-emc-storage-storage","category-emc-storage","category-storage","category-vnx","tag-clariion","tag-cx4","tag-emc","tag-howto","tag-remotelyanyhere","tag-vnx","tag-vnx-with-mcx","tag-vnx2"],"_links":{"self":[{"href":"https:\/\/www.penguinpunk.net\/blog\/wp-json\/wp\/v2\/posts\/2757","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.penguinpunk.net\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.penguinpunk.net\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.penguinpunk.net\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.penguinpunk.net\/blog\/wp-json\/wp\/v2\/comments?post=2757"}],"version-history":[{"count":6,"href":"https:\/\/www.penguinpunk.net\/blog\/wp-json\/wp\/v2\/posts\/2757\/revisions"}],"predecessor-version":[{"id":2827,"href":"https:\/\/www.penguinpunk.net\/blog\/wp-json\/wp\/v2\/posts\/2757\/revisions\/2827"}],"wp:attachment":[{"href":"https:\/\/www.penguinpunk.net\/blog\/wp-json\/wp\/v2\/media?parent=2757"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.penguinpunk.net\/blog\/wp-json\/wp\/v2\/categories?post=2757"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.penguinpunk.net\/blog\/wp-json\/wp\/v2\/tags?post=2757"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}