Copyright (c) EMC Corporation , 2007 Disk Array Subsystem Controller Model: CX700: SAN GBFCC4 DiagName: Extended POST DiagRev: Rev. 02.39 Build Date: Fri Jul 13 16:36:03 2007 StartTime: 01/19/2010 05:06:19 SaSerialNo: LKE00051202843 AabcdefgBCDEabFabcdGHabIabcJabKabLabMabcNabOabPabQabRabSabTabUabVabWabXYZAA Initializing back end FIBRE... PCI Config Reg: 2.4.1 0x0157 FCDMTL 0 [2.4.1] Dual Mode Fibre init - OSW DB PTR 0x397D6020 AG: init DMD to FC_SPEED_2_GBPS FCDMTL 0 [2.4.1] Cached memory - 0xF77B9 bytes @ 0x396DE800 FCDMTL 0 [2.4.1] Noncached memory - 0xC037F bytes @ 0x3961E420 (0x3961E420 phys) FCDMTL 0 [2.4.1] DVM Initialized FCDMTL 0 [2.4.1] IMQ base ptr = 39690000; IMQ length = 8000 Dualmode fibre init completed FCDMTL 0 [2.4.1] TPM Notify: st=0xA000000, flg=0x4, cmd=0x1 FCDMTL 0 [2.4.1] TPM Hndle API Event: cntx=0x397D64E4, evnt=0x4002, info=0x0 FCDMTL 0 [2.4.1] TPM Lnk Up: state=0xA000000, flg=0x84 Link Event: 0x00030005 Device Event (0xEF): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE8): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE4): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE2): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE1): 0x00030012, tach_ptr: 0x3C0486E0 DL waited 1s for discovery Target 0 is online Target 1 is online Target 2 is online Target 3 is online Target 4 is online Relocating Data Directory Boot Service (DDBS: Rev. 02.12)... Autoflash POST? DDBS: Read default MDDE off disk 2 DDBS: MDDE (Rev 2) on disk 2 DDBS: Read default DDE (0x400002) off disk 2 POST/DIAG image located at sector LBA 0x00012048 Initializing back end FIBRE... PCI Config Reg: 2.4.1 0x0157 FCDMTL 1 [2.4.1] Dual Mode Fibre init - OSW DB PTR 0x3959DBE0 AG: init DMD to FC_SPEED_2_GBPS FCDMTL 1 [2.4.1] Cached memory - 0xF77B9 bytes @ 0x396DEF20 FCDMTL 1 [2.4.1] Noncached memory - 0xC037F bytes @ 0x3961EB40 (0x3961EB40 phys) FCDMTL 1 [2.4.1] DVM Initialized FCDMTL 1 [2.4.1] IMQ base ptr = 39690000; IMQ length = 8000 Dualmode fibre init completed FCDMTL 1 [2.4.1] TPM Notify: st=0xA000000, flg=0x4, cmd=0x1 FCDMTL 1 [2.4.1] TPM Hndle API Event: cntx=0x3959E0A4, evnt=0x4002, info=0x0 FCDMTL 1 [2.4.1] TPM Lnk Up: state=0xA000000, flg=0x84 Link Event: 0x00030005 Device Event (0xEF): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE8): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE4): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE2): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE1): 0x00030012, tach_ptr: 0x3C0486E0 DL waited 1s for discovery Target 0 is online Target 1 is online Target 2 is online Target 3 is online Target 4 is online DDBS: Read default MDDE off disk 2 DDBS: MDDE (Rev 2) on disk 2 DDBS: Read default DDE (0x400002) off disk 2 POST/DIAG image located at sector LBA 0x00012048 Initializing back end FIBRE... PCI Config Reg: 2.4.1 0x0157 FCDMTL 2 [2.4.1] Dual Mode Fibre init - OSW DB PTR 0x3959DBE0 AG: init DMD to FC_SPEED_2_GBPS FCDMTL 2 [2.4.1] Cached memory - 0xF77B9 bytes @ 0x394A6340 FCDMTL 2 [2.4.1] Noncached memory - 0xC037F bytes @ 0x393E5F60 (0x393E5F60 phys) FCDMTL 2 [2.4.1] DVM Initialized FCDMTL 2 [2.4.1] IMQ base ptr = 39470000; IMQ length = 8000 Dualmode fibre init completed FCDMTL 2 [2.4.1] TPM Notify: st=0xA000000, flg=0x4, cmd=0x1 FCDMTL 2 [2.4.1] TPM Hndle API Event: cntx=0x3959E0A4, evnt=0x4002, info=0x0 FCDMTL 2 [2.4.1] TPM Lnk Up: state=0xA000000, flg=0x84 Link Event: 0x00030005 Device Event (0xEF): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE8): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE4): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE2): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE1): 0x00030012, tach_ptr: 0x3C0486E0 DL waited 1s for discovery Target 0 is online Target 1 is online Target 2 is online Target 3 is online Target 4 is online DDBS: Read default MDDE off disk 2 DDBS: MDDE (Rev 2) on disk 2 DDBS: Read default DDE (0x400002) off disk 2 POST/DIAG image located at sector LBA 0x00012048 Autoflash BIOS? Initializing back end FIBRE... PCI Config Reg: 2.4.1 0x0157 FCDMTL 3 [2.4.1] Dual Mode Fibre init - OSW DB PTR 0x39755FC0 AG: init DMD to FC_SPEED_2_GBPS FCDMTL 3 [2.4.1] Cached memory - 0xF77B9 bytes @ 0x394A6340 FCDMTL 3 [2.4.1] Noncached memory - 0xC037F bytes @ 0x393E5F60 (0x393E5F60 phys) FCDMTL 3 [2.4.1] DVM Initialized FCDMTL 3 [2.4.1] IMQ base ptr = 39470000; IMQ length = 8000 Dualmode fibre init completed FCDMTL 3 [2.4.1] TPM Notify: st=0xA000000, flg=0x4, cmd=0x1 FCDMTL 3 [2.4.1] TPM Hndle API Event: cntx=0x39756484, evnt=0x4002, info=0x0 FCDMTL 3 [2.4.1] TPM Lnk Up: state=0xA000000, flg=0x84 Link Event: 0x00030005 Device Event (0xEF): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE8): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE4): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE2): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE1): 0x00030012, tach_ptr: 0x3C0486E0 DL waited 1s for discovery Target 0 is online Target 1 is online Target 2 is online Target 3 is online Target 4 is online DDBS: Read default MDDE off disk 2 DDBS: MDDE (Rev 2) on disk 2 DDBS: Read default DDE (0x400001) off disk 2 BIOS image located at sector LBA 0x00011048 Initializing back end FIBRE... PCI Config Reg: 2.4.1 0x0157 FCDMTL 4 [2.4.1] Dual Mode Fibre init - OSW DB PTR 0x3959DB40 AG: init DMD to FC_SPEED_2_GBPS FCDMTL 4 [2.4.1] Cached memory - 0xF77B9 bytes @ 0x3965EEC0 FCDMTL 4 [2.4.1] Noncached memory - 0xC037F bytes @ 0x394DD780 (0x394DD780 phys) FCDMTL 4 [2.4.1] DVM Initialized FCDMTL 4 [2.4.1] IMQ base ptr = 39550000; IMQ length = 8000 Dualmode fibre init completed FCDMTL 4 [2.4.1] TPM Notify: st=0xA000000, flg=0x4, cmd=0x1 FCDMTL 4 [2.4.1] TPM Hndle API Event: cntx=0x3959E004, evnt=0x4002, info=0x0 FCDMTL 4 [2.4.1] TPM Lnk Up: state=0xA000000, flg=0x84 Link Event: 0x00030005 Device Event (0xEF): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE8): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE4): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE2): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE1): 0x00030012, tach_ptr: 0x3C0486E0 DL waited 1s for discovery Target 0 is online Target 1 is online Target 2 is online Target 3 is online Target 4 is online DDBS: Read default MDDE off disk 2 DDBS: MDDE (Rev 2) on disk 2 DDBS: Read default DDE (0x400001) off disk 2 BIOS image located at sector LBA 0x00011048 Initializing back end FIBRE... PCI Config Reg: 2.4.1 0x0157 FCDMTL 5 [2.4.1] Dual Mode Fibre init - OSW DB PTR 0x39755FC0 AG: init DMD to FC_SPEED_2_GBPS FCDMTL 5 [2.4.1] Cached memory - 0xF77B9 bytes @ 0x394A6A40 FCDMTL 5 [2.4.1] Noncached memory - 0xC037F bytes @ 0x393E6660 (0x393E6660 phys) FCDMTL 5 [2.4.1] DVM Initialized FCDMTL 5 [2.4.1] IMQ base ptr = 39470000; IMQ length = 8000 Dualmode fibre init completed FCDMTL 5 [2.4.1] TPM Notify: st=0xA000000, flg=0x4, cmd=0x1 FCDMTL 5 [2.4.1] TPM Hndle API Event: cntx=0x39756484, evnt=0x4002, info=0x0 FCDMTL 5 [2.4.1] TPM Lnk Up: state=0xA000000, flg=0x84 Link Event: 0x00030005 Device Event (0xEF): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE8): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE4): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE2): 0x00030012, tach_ptr: 0x3C0486E0 Device Event (0xE1): 0x00030012, tach_ptr: 0x3C0486E0 DL waited 1s for discovery Target 0 is online Target 1 is online Target 2 is online Target 3 is online Target 4 is online DDBS: Read default MDDE off disk 2 DDBS: MDDE (Rev 2) on disk 2 DDBS: Read default DDE (0x400001) off disk 2 BIOS image located at sector LBA 0x00011048 EndTime: 01/19/2010 05:07:10 DDBS: K10_REBOOT_DATA: Count = 0 DDBS: K10_REBOOT_DATA: State = 0 DDBS: K10_REBOOT_DATA: ForceDegradedMode = 0 DDBS: SP A Normal Boot Partition Disk 0 Read Error 0x0000018D Number Sectors: 1 LBA: 0x00001000 Buffer: 0x1000A31C Disk 0 Read Error 0x0000018D Number Sectors: 1 LBA: 0x00001400 Buffer: 0x1000A524 DDBS: Read default MDDE off disk 0 DDBS: MDDE (Rev 2) on disk 0 DDBS: Read default DDE (0x400007) off disk 0 Disk 0 Read Error 0x0000018D Number Sectors: 1 LBA: 0x0002284B Buffer: 0x10009F0C Disk 2 Read Error 0x00000187 Number Sectors: 1 LBA: 0x00001000 Buffer: 0x1000A31C Disk 2 Read Error 0x00000187 Number Sectors: 1 LBA: 0x00001400 Buffer: 0x1000A524 DDBS: Read default MDDE off disk 2 DDBS: MDDE (Rev 2) on disk 2 DDBS: Read default DDE (0x400008) off disk 2 Disk 2 Read Error 0x00000187 Number Sectors: 1 LBA: 0x0002284B Buffer: 0x1000A114 DDBS: Can't read MDB from first disk. DDBS: Can't read MDB from second disk. DDBS: Using first disk for boot - but inaccessible. FLARE image (0x00400007) located at sector LBA 0x0002284C Disk Set: 0 ErrorCode: 0x0000018D ErrorDesc: Device: BOOT PATH FRU: STORAGE PROCESSOR Description: Dual-Mode Fibre Driver Exchange Error! DualMode Driver Exchange Status: 0x1000000C Target ID: 0x00 EndError: ErrorTime: 01/19/2010 05:07:11